PA0U-W30
Qty | Price Each (£ GBP, EX VAT) |
---|---|
1 - 49 | 7.22 |
50 - 99 | 5.15 |
100 - 249 | 4.51 |
250 - 499 | 4.01 |
500 - 999 | 3.61 |
1000 - 2999 | 3.27 |
3000 - 4999 | 3.00 |
5000 - 9999 | 2.78 |
Lead time for additional qty approximately: 12 days
Full travel |
.075″ (1.91mm)
|
|
Working travel |
.050″ (1.27mm)
|
|
Spring force |
initial
|
at wkg travel
|
0.39oz (11g)
|
1.39oz (39g)
|
|
Current rating DC (max) |
2 Amps
|
|
Minimum test centres |
.025″ (.63mm)
|
|
Probe insertion tool |
Installation
The top of the PAO barrel is flared making its design different to many probes. This allows a high density of probes to be “pressed” directly into the probe plate eliminating the need for a receptacle or gluing. This “press-fit” feature also permits it to be installed in a variety of probe plate thicknesses and can be replaced relatively easily. The PAO is available with or without 30″ of 30 AWG insulated wire attached. It is installed into the probe plate with a probe insertion tool (part no. PITO) or a pair of tweezers. Shrink tubing can be used on alternate probes to provide strain relief in the termination and to reduce the possibility of electrical shorting.
To replace the probe, the wire is cut at the termination and the probe is then pushed out of the probe plate.